Integriti is an award-winning access control product by Inner Range that can be used to provide clocking information to Jarrison Time.
Configuring Integriti
Custom Field Setup:
In the Integriti application, click on the Administration tab and open Custom Fields
Complete the details accordingly:
Name: enter “Employee/Payroll Number”
Key Name: will be generated automatically (copy this key name to use later in JT)
Category Name: Custom Field
Field Type: Set to Text

Access Review Filter Setup:
In the Integriti application, click on the Home tab and open Filters.
Creating a filter helps Jarrison Time to only import clockings for the specific devices added to a filter.
Copy the “ID” to be used in JT

Configuring Jarrison Time
Open JT and go to ‘Setup’, ‘System Configuration’, Import Clockings tab
Select Integriti (API) from the dropdown for Location.
Complete the details accordingly:
Address: IP Address of Integriti Server
API Key: Secret key supplied by Integriti
Username: User that was created in Integriti
Password: User PW that was created in Integriti
Custom Field Key Name: Key Name that was created in Integriti for Employee Number as custom field (Case Sensitive)
Access Review Filter: Filter ID that was created in Integriti for specific Access Control Devices, if no filter was setup, set to 0

The system should now be ready to import clockings from the Integriti API.